Welcome to BUZY Networks

Ubiquiti, TP-Link, Teltonika & more

Free Shipping for Orders Over $500

Pickup Available in 5 States

Proudly Australian Owned

BUZY Networks
BUZY Networks

product details

APC NetShelter Rack PDU APDU10150ME — 7.4kW Metered

APC NetShelter Rack PDU Advanced (APDU10150ME) delivers metered power distribution for server and network racks with 7.4kW capacity at 230V/32A. Features 40 innovative 4-in-1 combination outlets in a compact 2.2″ form factor, plus real-time power monitoring via local display and remote access.

APC
APDU10150ME
Sale!
Free Shipping

Original price was: $1,750.00.Current price is: $1,554.00. inc GST.  

Good to Know

This product has NO ETA
When will it be in stock?

Available for Preorder

Stock?
Qty
ETA
Sydney
NO
No Stock
Melbourne
NO
No Stock
Brisbane
NO
No Stock
Adelaide
NO
No Stock
Perth
NO
No Stock

📢 Share This Product with a Friend!

BUZY NetworksBUZY's take on this product:

The APC NetShelter Rack PDU Advanced (APDU10150ME) delivers enterprise-grade power distribution for professional network and server rack deployments. This metered PDU provides 7.4kW capacity at 230V/32A, offering real-time power monitoring through both a local display and remote access capabilities, allowing you to track consumption and receive notifications before potential overload situations occur. With its innovative 4-in-1 combination outlets, each of the 40 outlets can be configured as C13, C19, C15, or C21 connections, providing unmatched deployment flexibility for diverse equipment requirements.

  • Maximum outlet density: 40 outlets in a compact 2.2-inch wide form factor, ideal for high-density rack environments
  • Color-coded outlets by breaker: Simplifies installation and load balancing across circuits
  • Power Sharing capability: Dual Gigabit Ethernet ports enable cascaded PDUs to maintain network management functionality even during AC power loss
  • High-temperature rated: Approved for full-load operation up to 60°C (140°F), ensuring reliability in today’s demanding, high-density deployments

For IT professionals managing UniFi network deployments, server racks, or mixed infrastructure environments, this advanced PDU provides the power monitoring and distribution control essential for maintaining uptime and preventing circuit overloads. The metered functionality gives you visibility into actual power consumption across your rack—critical when planning capacity for additional switches, access points, or servers. The dual Ethernet ports with Power Sharing ensure continuous network management communication, allowing your monitoring systems to maintain awareness of power conditions even during outages, making this an intelligent choice for professional installations where visibility and reliability are non-negotiable.

Product Description

APC NetShelter Rack PDU Advanced, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets

APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 40 outlets in a 2.2″ wide form factor. Outlets on the PDUs are color coded by breaker to simplify deployment. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today’s high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected.
Colour Black
Product or component type PDU
PDU type Metered
Cord length 3.0 m
Input Voltage230 V 1 phase
Product certifications- TAA compliance, UKCA
Standards- CE, EN 62368-1
Ambient air temperature for operation -5…60 °C
Relative humidity 5…95 %
Operating altitude 0…10000 ft
Ambient air temperature for storage-25…65 °C
Storage Relative Humidity5…95 %
Storage altitude0.0000000000…15240.0000000000 m

Reviews

There are no reviews yet

Only logged in customers who have purchased this product may leave a review.

  • Message Service 08 9331 3455
    We check all messages & return genuine enquiries
  • PO Box 4002, Coolbellup, WA, 6163
  • Contact
© 2026 BUZY Networks Australia. A division of Perth Technical Services Pty Ltd. All rights reserved. E&OE.